When a VLT drive enters a braking state (decelerating a load quickly), it pumps excess energy generated by the motor back into the DC bus. To prevent overvoltage, this energy is diverted to a brake resistor to be burned off as heat. Error 2563 triggers when the drive measures the resistance of the connected brake resistor and finds it is significantly lower than the calculated or expected value, or effectively zero ohms. Movies South Hindi Dubbed High Quality New | Ssr

Error Name: Brake Resistor Shorted Error Type: Critical Fault Applicable Units: VLT AutomationDrive FC 302, VLT HVAC Drive FC 102, VLT Aqua Drive FC 202 1. What Does Error 2563 Mean? Error Code 2563 indicates that the frequency converter has detected a short circuit or a dangerously low resistance value in the external brake resistor circuit. User Manual - Fresenius 6008